Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.303
Filtrar
1.
Front Endocrinol (Lausanne) ; 15: 1355383, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628591

RESUMO

Purpose: Radiofrequency ablation (RFA) is an effective and safe modality for the treatment of thyroid nodules. Nodule rupture is a major complication of RFA. There is little known on the natural history of nodule rupture due to a lack of clinical experience and no consensus on its management. A comprehensive review of nodule rupture presentation, diagnosis, and management is needed. Methods: We report a case of nodule rupture and conduct a literature review. A total of 33 patients experiencing nodule rupture after RFA were included, and their clinical presentation, management, and outcomes were collected and analyzed. Results: Nodule rupture presents with acute swelling (90.3%) and pain (77.4%) within 7 months of RFA procedure, most commonly due to disruption of the anterior thyroid capsule (87%), and can be diagnosed with ultrasonography. Most ruptures can be managed conservatively, exemplified by our reported case. There are no reported cases of long-term sequalae. Conclusion: Nodule rupture is the second most common major complication of RFA. Based on the available evidence, we propose a treatment algorithm for nodule rupture and recommendations for future data collection to address gaps in our understanding of rupture etiology and effective management.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/métodos
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584395

RESUMO

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Recidiva
4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Cateteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
J Cardiothorac Surg ; 19(1): 190, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589914

RESUMO

OBJECTIVES: Although risk factors for unsuccessful Maze procedure have been demonstrated, an appropriate patient selection is still controversial. In our institute, Maze procedure is indicated for those whom normal sinus rhythm (NSR) was reestablished by intraoperative direct cardioversion (DC) after ventricular unloading by total cardiopulmonary bypass. The purpose of this study was to evaluate the effectiveness of our indication criteria for Maze procedure in patients with mitral valve disease. METHODS: Between October 2012 and October 2021, MAZE was indicated in 55 patients in whom normal sinus rhythm (NSR) was reestablished by intraoperative direct current cardioversion (DC). Three endpoints and predictors were examined: disappearance of atrial fibrillation (AF), NSR, and A-wave detection. RESULTS: Restoration of NSR by intraoperative DC was confirmed in 43 patients, and these patients underwent MAZE. AF disappeared in 39 patients (90.7%), and F-wave ≥ 0.1 mV was a significant predictive factor (odds ratio (OR) 20.99, 95% CI 1.22-1079.06). NSR was reestablished in 36 patients (83.7%), and F-wave ≥ 0.1 mV (odds ratio 15.62, 95% CI 1.62-359.86) + AF history ≤ 3 years (OR 8.30, 95% CI 1.09-177.04) were significant predictors. A-wave detection was confirmed in 26 patients (60.5%), and left atrial diameter ≤ 55 mm was a significant predictor (OR 5.22, 95% CI 1.28-24.79). CONCLUSIONS: Intraoperative DC after ventricular unloading resulted effective patient selection for concomitant Maze procedure. F-wave and AF history were predictive factor of electrical restoration of AF, and left atrial diameter was predictive factor of restoration of atrial function.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral/cirurgia , Procedimento do Labirinto , Seleção de Pacientes , Estenose da Valva Mitral/cirurgia , Resultado do Tratamento , Doenças das Valvas Cardíacas/complicações , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos
6.
Skin Res Technol ; 30(4): e13652, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572582

RESUMO

OBJECTIVE: To investigate whether compression therapy after thermal ablation of varicose veins can improve the prognosis of patients. METHODS: Systematic research were applied for Chinese and English electronic databases(PubMed, Web of Science, Cochrane Library, CNKI, Wanfang, VIP Databases). Eligible prospective studies that comparing the efficacy of compression therapy and non-compression therapy on patients after thermal ablation of varicose veins were included. The interest outcome such as pain, quality of life (QOL), venous clinical severity score (VCSS), time to return to work and complications were analyzed. RESULTS: 10 studies were of high quality, and randomized controlled trials involving 1,545 patients met the inclusion criteria for this study. At the same time, the meta-analysis showed that the application of compression therapy improved pain (SMD: -0.51, 95% CI: -0.95, -0.07) but exhibited no statistically significant effect on QOL (SMD: 0.04, 95% CI: -0.08, 0.16), VCSS (MD: -0.05, 95% CI: -1.19, 1.09), time to return to work (MD: -0.43, 95% CI: -0.90, 0.03), total complications (RR: 0.54, 95% CI: 0.27, 1.09), and thrombosis (RR: 0.71, 95% CI: 0.31, 1.62). CONCLUSION: Compression therapy after thermal ablation of varicose veins can slightly relieve pain, but it has not been found to be associated with improvement in other outcomes.


Assuntos
Ablação por Cateter , Terapia a Laser , Varizes , Humanos , Qualidade de Vida , Estudos Prospectivos , Terapia a Laser/métodos , Varizes/cirurgia , Varizes/etiologia , Dor/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38597211

RESUMO

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Fenótipo , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
Int Braz J Urol ; 50(3): 277-286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598830

RESUMO

PURPOSE: CT-guided MWA is a safe and effective tool that should be utilized in the treatment of small renal masses (SRMs). We aim to clarify the utility of CT-guided MWA by examining patient outcomes such as recurrence, treatment success, changes in renal function, and complications. METHODS: A retrospective review of consecutive patients with SRMs who underwent same day renal mass biopsy (RMB) and CT-guided MWA between 2015 and 2022 was performed. Treatment safety was assessed by 30-day complications according to the Clavien-Dindo system and change in eGFR >30 days post-procedure. Treatment efficacy was defined by local recurrence and incomplete treatment rates and calculated using the Kaplan-Meier method. RESULTS: A total of 108 renal masses were found in 104 patients. The overall complication rate was 7.4% (8/108), of which 4 were major complications (3.7%). For those with renal function available >30 days post ablation, the median eGFR was 47.2 (IQR: 36.0, 57), compared to 52.3 (IQR: 43.7, 61.5) pre-ablation, p<0.0001. 5-year local recurrence free survival was 86%. Among those with biopsy proven malignancy (n= 66), there were five local recurrences (7.54%) occurring at a median of 25.1 months (IQR 19.9, 36.2) and one case (1.5%) of incomplete treatment. CONCLUSIONS: As the medical field continues to evolve towards less invasive interventions, MWA offers a valuable tool in the management of renal masses. With low major complication and recurrence rates, our findings support the utility of CT-guided MWA as a tool for treatment of SRMs.


Assuntos
Técnicas de Ablação , Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Humanos , Neoplasias Renais/patologia , Carcinoma de Células Renais/patologia , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Estudos Retrospectivos , Ablação por Cateter/métodos
9.
J Cardiothorac Surg ; 19(1): 238, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632637

RESUMO

BACKGROUND: There is insufficient information regarding the bleeding sites and surgical strategies of cardiac tamponade during catheter ablation for atrial fibrillation (AF). CASE PRESENTATION: Of the five patients with cardiac tamponade, three required surgical intervention and two required pericardiocentesis. In the first case of three cardiac tamponades requiring surgical intervention, considering that the peripheral route was used, the catecholamines did not reach the heart, and due to unstable vital signs, venoarterial extracorporeal membrane oxygenation (VA-ECMO) was inserted. No bleeding point was identified, but a thrombus had spread around the left atrium (LA) with diverticulum. Hemostasis was achieved with adhesives placed around the LA under on-pump beating. In the second case, pericardiocentesis was performed, but the patient showed heavy bleeding and unstable vital signs. Thus, VA-ECMO was inserted. Heavy bleeding was expected, and safety was enhanced by attaching a reservoir to the VA-ECMO. The bleeding point was found between the left upper pulmonary artery and LA under cardiac arrest to obtain a good surgical view for suturing repair. In the third case, the LA diverticulum was damaged. Pericardiocentesis resulted in stable vitals, but sustained bleeding was present. A bleeding point was found at the LA diverticulum, and suture repair under on-pump beating was performed. CONCLUSIONS: When cardiac tamponade occured in any patient with LA diverticulum, treatment could not be completed with pericardiocentesis alone, and thoracotomy was likely to be necessary. If the bleeding point could be confirmed, suturing technique is a more reliable surgical strategy than adhesive alone that leads to pseudoaneurysm. If the bleeding point is unclear, it is important to confirm the occurrence of LA diverticulum using a preoperative CT, and if confirmed, cover it with adhesive due to a high possibility of diverticulum bleeding. The necessity of CPB should be determined based on whether these operations can be completed while maintaining vital stability.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Divertículo , Humanos , Tamponamento Cardíaco/cirurgia , Toracotomia , Átrios do Coração/cirurgia , Fibrilação Atrial/cirurgia , Hemorragia/etiologia , Ablação por Cateter/métodos , Divertículo/cirurgia , Resultado do Tratamento
10.
Sci Rep ; 14(1): 8974, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637577

RESUMO

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Telas Cirúrgicas , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Arritmias Cardíacas , Resultado do Tratamento
11.
Medicine (Baltimore) ; 103(16): e37543, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640303

RESUMO

BACKGROUND: Tachycardia-bradycardia syndrome (TBS) is a subtype of sick sinus syndrome characterized by prolonged sinus pause (≥3 s) following termination of tachyarrhythmias, primarily atrial fibrillation (AF). There is controversy regarding whether the long-term prognosis of AF ablation is superior to pacemaker implantation. This study aimed to compare the effects of AF ablation and pacemaker therapy in patients with TBS. METHODS: We conducted a comprehensive search of electronic databases, including PubMed, Cochrane, EmBase, Web of Science, and Chinese BioMedical, up until December 1, 2023. We included studies that reported the effects of AF ablation vs pacemaker therapy in patients with TBS. From this search, we identified 5 studies comprising 843 participants with TBS who underwent catheter AF ablation or pacemaker therapy. RESULTS: Our meta-analysis revealed that AF ablation and pacemaker therapy had similar effects on cardiovascular death (odds ratio [OR] = 0.62 and 95% confidence interval [CI]: 0.14-2.65), procedural complications (OR = 1.53 and 95% CI: 0.67-3.48), and cardiovascular rehospitalization (OR = 0.57 and 95% CI: 0.26-1.22). However, AF ablation provided greater benefits than pacemaker therapy in terms of all-cause mortality (OR = 0.37 and 95% CI: 0.17-0.82), thromboembolism (OR = 0.25 and 95% CI: 0.12-0.49), stroke (OR = 0.28 and 95% CI: 0.13-0.57), heart failure (OR = 0.27 and 95% CI: 0.13-0.56), freedom from AF (OR = 23.32 and 95% CI: 7.46-72.92), and prevention of progression to persistent AF (OR = 0.12 and 95% CI: 0.06-0.24). Furthermore, AF ablation resulted in a reduced need for antiarrhythmic agents (OR = 0.21 and 95% CI: 0.08-0.59). CONCLUSION: AF ablation can effectively reduce the risk of all-cause mortality, thromboembolism, stroke, heart failure, and progression to persistent AF in patients with TBS. Additionally, it may eliminate the need for further pacemaker therapy in most cases after ablation. Therefore, AF ablation is considered superior to pacemaker therapy in the management of patients with TBS.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Marca-Passo Artificial , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Síndrome do Nó Sinusal/terapia , Bradicardia/terapia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Taquicardia/terapia , Ablação por Cateter/métodos , Acidente Vascular Cerebral/etiologia , Insuficiência Cardíaca/etiologia , Tromboembolia/etiologia
12.
Zhonghua Gan Zang Bing Za Zhi ; 32(3): 208-213, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38584101

RESUMO

Objective: To investigate the spatial distribution pattern of local tumor progression (LTP) for hepatocellular carcinoma (HCC) ≤5 cm after microwave ablation. Methods: A retrospective analysis was performed on 169 HCCs with matched MRI before and after ablation from December 2009 to December 2019. A tumor MRI was reconstructed using three-dimensional visualization technology. LTP was classified as contact or non-contact, early or late stage, according to whether LTP was in contact with the edge of the ablation zone and the occurrence time (24 months). The tumor-surrounded area was divided into eight quadrants by using the eight-quadrant map method. An analysis was conducted on the spatial correlation between the quadrant where the ablative margin (AM) safety boundary was located and the quadrant where different types of LTP occurred. The t-test, or rank-sum test, was used for the measurement data. 2-test for count data was used to compare the difference between the two groups. Results: The AM quadrant had a distribution of 54.4% LTP, 64.2% early LTP stage, and 69.1% contact LTP, suggesting this quadrant was much more concentrated than the other quadrants (P < 0.001). Additionally, the AM quadrant had only 15.2% of non-contact type LTP and 17.1% of late LTP, which was not significantly different from the average distribution probability of 12.5% (100/8%) among the eight quadrants (P = 0.667, 0.743). 46.6% of early contact type LTP was located at the ablation needle tip, 25.2% at the body, and 28.1% at the caudal, while the location distribution probabilities of non-early contact LTP were 34.8%, 31.8%, and 33.3%, respectively. Conclusion: LTP mostly occurs in areas where the ablation safety boundary is the shortest. However, non-contact LTP and late LTP stages exhibit the feature of uniform distribution. Thus, this type of LPT may result from an inadequate non-ablation safety boundary.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Imageamento Tridimensional/métodos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
13.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581024

RESUMO

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Teorema de Bayes , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
14.
J Cardiothorac Surg ; 19(1): 187, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582871

RESUMO

OBJECTIVE: To analyze the relationship between the thickness of the left atrial posterior wall and the low and no voltage zones in the left atrial posterior wall in patients with atrial fibrillation (AF). METHODS: 61 patients admitted to our cardiology department for AF and radiofrequency ablation of AF from January 1, 2020 to May 30, 2022 were enrolled according to inclusion and exclusion criteria. The atrial wall thickness was measured by CT scan. Baseline data, preoperative cardiac ultrasound data, preoperative biochemical parameters, low voltage zone (fibrotic zone) and no voltage zone (scar zone) in the left atrial posterior wall area, and various parameters of posterior left atrial wall thickness were collected. RESULTS: The differences of the thickness between the upper, middle and lower mean levels of the left atrial posterior wall were statistically significant (P = 0.004). The results showed that body mass index was weakly positively correlated with the mean level of total left atrial posterior wall thickness (r = 0.426, P = 0.001) and was statistically significant. The remaining indices were positively or negatively correlated with the mean level of total left atrial posterior wall thickness, but none were statistically significant (P > 0.05). CONCLUSIONS: Both left atrial posterior wall low-voltage zone and voltage-free zone were positively correlated with the mean total left atrial posterior wall thickness, and left atrial posterior wall low-voltage zone and voltage-free zone were significantly positively correlated. Body mass index was weakly positively correlated with total left atrial posterior wall thickness.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Ablação por Cateter/métodos , Átrios do Coração/patologia , Fibrose , Cicatriz , Resultado do Tratamento
15.
PLoS One ; 19(4): e0300309, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38578781

RESUMO

Radiofrequency ablation (RFA) using the CARTO 3D mapping system is a common approach for pulmonary vein isolation to treat atrial fibrillation (AF). Linkage between CARTO procedural data and patients' electronical health records (EHR) provides an opportunity to identify the ablation-related parameters that would predict AF recurrence. The objective of this study is to assess the incremental accuracy of RFA procedural data to predict post-ablation AF recurrence using machine learning model. Procedural data generated during RFA procedure were downloaded from CARTONET and linked to deidentified Mercy Health EHR data. Data were divided into train (70%) and test (30%) data for model development and validation. Automate machine learning (AutoML) was used to predict 1 year AF recurrence, defined as a composite of repeat ablation, electrical cardioversion, and AF hospitalization. At first, AutoML model only included Patients' demographic and clinical characteristics. Second, an AutoML model with procedural variables and demographical/clinical variables was developed. Area under receiver operating characteristic curve (AUROC) and net reclassification improvement (NRI) were used to compare model performances using test data. Among 306 patients, 67 (21.9%) patients experienced 1-year AF recurrence. AUROC increased from 0.66 to 0.78 after adding procedural data in the AutoML model based on test data. For patients with AF recurrence, NRI was 32% for model with procedural data. Nine of 10 important predictive features were CARTO procedural data. From CARTO procedural data, patients with lower contact force in right inferior site, long ablation duration, and low number of left inferior and right roof lesions had a higher risk of AF recurrence. Patients with persistent AF were more likely to have AF recurrence. The machine learning model with procedural data better predicted 1-year AF recurrence than the model without procedural data. The model could be used for identification of patients with high risk of AF recurrence post ablation.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia
16.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579029

RESUMO

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Comunicação Interatrial , Ablação por Radiofrequência , Humanos , Masculino , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Retrospectivos , Punções/efeitos adversos , Punções/métodos , Aorta/cirurgia , Comunicação Interatrial/cirurgia , Fibrilação Atrial/cirurgia
17.
Pan Afr Med J ; 47: 20, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38524104

RESUMO

In this case report, we will discuss a 74-year-old female who presented with a chief complaint of abdominal pain, bloating, anorexia, and nausea for four days which preceded after catheter ablation and anhydrous ethanol infusion vein of Marshall (VOM) one month prior. She was admitted and treated as a general patient in the general ward. After hospital admission, a pericardiocentesis was guided by B-scan ultrasonography, resulting in the extraction of 20ml of pericardial effusion, followed by catheterization for drainage. The key takeaway in this report is that anhydrous ethanol infusion VOM may not always be without risks. Hence, during the procedure, it is imperative to carefully administer the appropriate volume of anhydrous ethanol into the VOM to prevent vessel damage and associated complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Pericardite , Feminino , Humanos , Idoso , Fibrilação Atrial/cirurgia , Etanol/efeitos adversos , Infusões Intravenosas , Vasos Coronários/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
18.
J Am Heart Assoc ; 13(6): e033146, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471838

RESUMO

BACKGROUND: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation. METHODS AND RESULTS: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (P=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; P=0.037). CONCLUSIONS: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Cateteres , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
19.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471835

RESUMO

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Angiopoietina-2 , Interleucina-6 , Modelos Estatísticos , Volume Sistólico , Remodelação Ventricular , Fatores de Risco , Prognóstico , Recidiva , Função Ventricular Esquerda , Biomarcadores , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
20.
J Am Heart Assoc ; 13(7): e032722, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533962

RESUMO

BACKGROUND: Guidelines recommend prioritizing treatment with antiarrhythmic drugs before referral of patients with atrial fibrillation to ablation, delaying a potential subsequent ablation. However, delaying ablation may affect ablation outcomes. We sought to investigate the impact of duration from diagnosis to ablation on the risk of atrial fibrillation recurrence and adverse events. METHODS AND RESULTS: Using Danish nationwide registries, all patients with first-time ablation for atrial fibrillation were identified and included from 2010 to 2018. Patients were divided into 4 groups by diagnosis-to-ablation time: <1.0 year (early ablation), 1.0 to 1.9 years, 2.0 to 2.9 years, and >2.9 years (late ablation). The primary end point was atrial fibrillation recurrence after the 90-day blanking period, defined by admission for atrial fibrillation, cardioversions, use of antiarrhythmic drugs, or repeat atrial fibrillation ablations. The secondary end point was a composite end point of heart failure, ischemic stroke, or death, and each event individually. The study cohort consisted of 7705 patients. The 5-year cumulative incidence of atrial fibrillation recurrence in the 4 groups was 42.9%, 54.8%, 55.9%, and 58.4%, respectively. Hazard ratios were 1.20 (95% CI, 1.07-1.35), 1.29 (95% CI, 1.13-1.47), and 1.40 (95% CI, 1.28-1.53), respectively, with the early ablation group as reference. The hazard ratio for the combined secondary end point was 1.22 (95% CI, 1.04-1.44) in the late ablation group compared with the early ablation group. CONCLUSIONS: In patients undergoing ablation for atrial fibrillation, early ablation was associated with a significantly lower risk of atrial fibrillation recurrence. Furthermore, the associated risk of heart failure, ischemic stroke, or death was significantly lower in early-compared with late-ablation patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , AVC Isquêmico , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Antiarrítmicos/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , AVC Isquêmico/etiologia , Dinamarca/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...